| MODEL | JCC-1000S |
| PRIME POWER (KVA/KW) | 1000/800 |
| STANDBY POWER(KVA/KW) | 1100/880 |
| Rated voltage(V) | 400/230 |
| Rated speed(rpm) | 1500 |
| Rated frequency(Hz) | 50 |
| Power factor | 0.8 |
| Ambient temperature(°C) | 40 |
| Altitude(m) | 1000 |
| Connection type | 3 phase 4 wires |
| ENGINE MANUFACTURER | CCEC |
| Model | KTA38-G5 |
| Rated Power(kW) | 880 |
| No. of cylinders & configuration | In-Line 12 cylinders |
| Method of operation | 4-stroke |
| Speed regulation | Electronic Governor |
| Starting system | DC 24V Electronic start |
| Cooling method | Closed-circuit cooling system |
| Total displacement(L) | 37.8 |
| Compression ratio | 13.9:1 |
| Bore×Stroke(mm) | 159×159 |
| 100% Load fuel consumption(L/h) | 209 |
| Number of Phase | 3 |
| Connection Type | 3Phase and 4Wires |
| Number of Bearing | 1 |
| Power Factor | 0.8 |
| Protection Grade | IP23 |
| Terminal | 12 |
| Winding/ Pitch | 100% Copper 2/3 Pitch |
| Cooling Fan | Cast alloy aluminum |
| Exciter Type | Brushless, Self-Exciting |
| Insulation Class, Temperature Rise | H/H |
| Telephone Influence Factor( TIF) | TIF <50 / THF<2% |
| Total Harmonic TGH/THC | <1.5% at no load / <5% at load |
| Voltage Regulation, Steady State | ≤±1% |
| Sustained Short-Circuit Current | 300%(3 in):10s |
| CONTROL SYSTEM | SMARTGEN SERIES |
| Technical Data | ||||||||
| Gensets | Diesel Engine(50hz/1500rpm) | Alternator(50hz/1500rpm) | ||||||
| Model | Gensets power(KW/KVA) | Engine model |
Engine power/kw | JLT -POWER |
||||
| Prime | Standby | Prime | Standby | |||||
| JDC22 | 16 | 20 | 18 | 22 | 4B3.9-G11 | 20 | 22 | JLT184ES(16KW) |
| JDC30 | 22 | 28 | 24 | 30 | 4B3.9-G1 | 24 | 27 | JLT184F(22KW) |
| JDC30 | 22 | 28 | 24 | 30 | 4B3.9-G2 | 24 | 27 | JLT184F(22KW) |
| JDC34 | 25 | 31 | 28 | 34 | 4B3.9-G12 | 27 | 28 | JLT184G(25KW) |
| JDC44 | 32 | 40 | 35 | 44 | 4BT3.9-G1 | 36 | 40 | JLT184J(32KW) |
| JDC44 | 32 | 40 | 35 | 44 | 4BT3.9-G2 | 36 | 40 | JLT184J(32KW) |
| JDC62 | 45 | 56 | 50 | 62 | 4BTA3.9-G2 | 50 | 55 | JLT224E(50KW) |
| JDC72 | 52 | 65 | 57 | 72 | 4BTA3.9-G2 | 58 | 64 | JLT224FS(54KW) |
| JDC88 | 64 | 80 | 70 | 88 | 4BTA3.9-G11 | 70 | 80 | JLT224GS(64KW) |
| JDC105 | 76 | 95 | 84 | 105 | 4BTA3.9-G13 | 87 | 97 | JLT224GM(75KW) |
| JDC110 | 80 | 100 | 88 | 110 | 4BTAA3.9-G3 | 96 | 106 | JLT274C(80KW) |
| JDC103 | 75 | 94 | 83 | 103 | 6BT5.9-G1 | 86 | 92 | JLT224GM(75KW) |
| JDC94 | 68 | 85 | 75 | 94 | 6BT5.9-G2 | 86 | 92 | JLT224GM(75KW) |
| JDC110 | 80 | 100 | 88 | 110 | 6BT5.9-G2 | 96 | 106 | JLT274DS(90KW) |
| JDC124 | 90 | 113 | 99 | 124 | 6BTA5.9-G2 | 106 | 116 | JLT274DS(90KW) |
| JDC154 | 112 | 140 | 123 | 154 | 6BTAA5.9-G2 | 120 | 130 | JLT274E(112KW) |
| JDC165 | 120 | 150 | 132 | 165 | 6BTAA5.9-G12 | 140 | 155 | JLT274FS(120KW) |
| JDC206 | 150 | 188 | 165 | 206 | 6CTA8.3-G1 | 163 | 180 | JLT274G(145KW) |
| JDC206 | 150 | 188 | 165 | 206 | 6CTA8.3-G2 | 163 | 180 | JLT274G(145KW) |
| JDC220 | 160 | 200 | 176 | 220 | 6CTAA8.3-G2 | 183 | 200 | JLT274H(160KW) |
| JDC250 | / | / | 200 | 250 | 6CTAA8.3-G9 | / | 213 | JLT274J(180KW) |
| JCC275 | 200 | 250 | 220 | 275 | NTA855-G1 | 240 | 264 | JLT274K(200KW) |
| JCC303 | 220 | 275 | 242 | 303 | NTA855-G1A | 264 | 291 | JLT444D(240KW) |
| JCC344 | 250 | 313 | 275 | 344 | NTA855-G1B | 284 | 321 | JLT444ES(260KW) |
| JCC344 | 250 | 313 | 275 | 344 | NTA855-G2 | 284 | 321 | JLT444ES(260KW) |
| JCC385 | 280 | 350 | 308 | 385 | NTA855-G2A | 312 | 343 | JLT444E(280KW) |
| JCC385 | 280 | 350 | 308 | 385 | NTA855-G4 | 317 | 351 | JLT444E(280KW) |
| JCC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | 343 | 407 | JLT444FS(300KW) |
| JCC450 | / | / | 360 | 450 | NTAA855-G7A | / | 407 | JLT444F(320KW) |
| JCC413 | 300 | 375 | 330 | 413 | KTA19-G2 | 336 | 369 | JLT444FS(300KW) |
| JCC495 | 360 | 450 | 396 | 495 | KTA19-G3 | 403 | 448 | JLT444FM(360KW) |
| JCC550 | 400 | 500 | 440 | 550 | KTA19-G3A | 448 | 504 | JLT544D(400KW) |
| JCC550 | 400 | 500 | 440 | 550 | KTA19-G4 | 448 | 504 | JLT544D(400KW) |
| JCC605 | 440 | 550 | 484 | 605 | KTAA19-G5 | 470 | 555 | JLT544ES(450KW) |
| JCC633 | 460 | 575 | 506 | 633 | KTAA19-G6 | 520 | 570 | JLT544E(480KW) |
| JCC688 | / | / | 550 | 688 | KTAA19-G6A | / | 610 | JLT544FS(500KW) |
| JCC650 | / | / | 520 | 650 | KTA19-G8 | / | 575 | JLT544E(480KW) |
| JCC688 | 500 | 625 | 550 | 688 | KTAA19-G8A | 550 | 610 | JLT544FS(500KW) |
| JCC756 | 550 | 688 | 605 | 756 | KTA19-G9A | 600 | 660 | JLT544FM(560KW) |
| JCC798 | 580 | 725 | 638 | 798 | KTA38-GA | 647 | 711 | JLT634B(600KW) |
| JCC784 | 570 | 713 | 627 | 784 | KTA38-G1 | 634 | 711 | JLT634B(600KW) |
| JCC825 | 600 | 750 | 660 | 825 | KTA38-G2 | 664 | 731 | JLT634B(600KW) |
| JCC880 | 640 | 800 | 704 | 880 | KTA38-G2B | 711 | 789 | JLT634C(640KW) |
| JCC1000 | 728 | 910 | 801 | 1001 | KTA38-G2A | 813 | 895 | JLT634D(728KW) |
| JCC1100 | 800 | 1000 | 880 | 1100 | KTA38-G5 | 880 | 970 | JLT634E(800KW) |
| JCC1238 | 900 | 1125 | 990 | 1238 | KTA38-G9E | 990 | 1089 | JLT634F(904KW) |
| JCC1375 | 1000 | 1250 | 1100 | 1375 | KTA38-G9A | 1100 | 1210 | JLT634G(1000KW) |
| JCC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | 1097 | 1207 | JLT634G(1000KW) |
| JCC1513 | 1100 | 1375 | 1210 | 1513 | KTA50-G7E | 1210 | 1320 | JLT634GM(1120KW) |
| JCC1540 | 1120 | 1400 | 1232 | 1540 | KTA50-G8 | 1200 | 1320 | JLT634GM(1120KW) |
| JCC1650 | 1200 | 1500 | 1320 | 1650 | KTA50-GS8 | 1287 | 1429 | JLT734C(1240KW) |
| JCC1843 | 1340 | 1675 | 1474 | 1843 | KTA50-G15X | 1491 | 1656 | JLT734D(1320KW) |
| JCC2063 | 1500 | 1875 | 1650 | 2063 | KTA50-G16A | 1650 | 1760 | JLT734E(1520KW) |
| JCC2200 | 1600 | 2000 | 1760 | 2200 | KTA50-G16B | 1760 | 1810 | JLT734F(1664KW) |
| CORROSION RESISTANT RADIATOR | SOLID DAMPING FOOT | AIR FILTER |
High quality and low noise radiators, with anti-rust paint to add, ensure that your machine will never old, mildew, corrosion resistance, safety. |
solid damping foot is stamping forming by 3-5 mm high strength steel plate, with metal cover to protect rubber. | piston, piston ring, valve and valve seat with more than 99.5% of original filtration efficiency |
| Digital control panel | ELECTRONIC COMPONENTS | THICKENED BENDED UNDERFRAME |
| use of three remote control unit control panel,integrated digital, intelligen't technology, compact structure, simple wiring, high reliability. |
Cooperate with well-known electronic component manufacturers such as Delixi and Chint to provide customers with long-life,high-quality and very accurate machines | 5MM thickened bent chassis, double-layer painting, improve corrosion resistance. Prevent the unit chassis from being corroded |
Q1: How can I determine the appropriate rated power for my application?
A1: Calculate your total load requirement and add a 20-30% safety margin Consider both continuous (primary) and backup power requirements simultaneously
Q2: Can the generator output multiple voltages?
A2: Yes, most models support adjustable voltage (e.g. 380V/400V/415V) and frequency (50Hz/60Hz)
Q3: What engine brands do you offer?
A3: We collaborate with many international leading brands to ensure reliability and efficiency
Q4: What is the noise level of the generator?
A4: The optional silent canopy reduces noise to ≤ 75dB (A) at 1m, while the ultra quiet canopy reduces noise to 60dB (A) at 1m, in compliance with environmental regulations
Q5: What are the startup methods?
A5: Standard electric start with backup battery Optional remote start and auto start modules
Q6: Can multiple generators be connected in parallel?
A6: Yes, it comes with a synchronous control panel for load sharing and redundancy
Q7: What is the working temperature range?
A7: -10 ° C to 40 ° C. Low temperature dedicated cold start kit and high-temperature radiator upgrade
Q8: How often does maintenance need to be carried out?
A8: Routine inspection every 200 hours; Main service every 1000-2000 hours (depending on the engine)
Q9: What is the warranty period?
A9: Standard 1 year/1200 hours (whichever comes first) Extended warranty applicable to critical applications
Q10: Are spare parts available at any time?
A10: Yes, we maintain comprehensive inventory and provide global shipping
Q11: Can the generator be remotely monitored?
A11: Yes, the optional IoT module can monitor performance and diagnose in real-time
Q12: How does the generator handle high humidity and salt spray in island environments?
A12: Our generator has anti-corrosion treatment (such as galvanized casing, marine grade paint) and sealed electrical components to resist salt spray and humidity The optional upgrade of ship specifications further enhances durability under harsh coastal conditions
Q13: Is the generator suitable for the extreme temperature fluctuations commonly seen on the island?
A13: Yes It operates in an adaptive cooling/heating system ranging from -5 ° C to 50 ° C For tropical islands, high-temperature radiators can be used; For colder areas, the cold start kit ensures reliability
Q14: How to prevent damage caused by strong winds or storms on islands?
A14: We provide reinforced foundation frames and windproof canopies (capable of withstanding winds of 120 kilometers per hour) The safety anchoring kit is recommended to be installed in exposed areas
Q15: Can generators located on isolated islands be remotely monitored?
A15: Yes A system that supports the Internet of Things provides real-time alerts on fuel levels, performance, or faults, which is crucial for islands with limited on-site personnel
Q16: How often should maintenance be carried out in salt rich environments?
A16: More frequent inspections are required: visual inspection of corrosion filters every month, replacement every 150 operating hours (compared to 200 inland), and comprehensive anti-corrosion treatment every year